Showing results: 496 - 510 of 1445 items found.
-
PL-10N -
PINTEK Electronics
*MODEL:PL-10N*IMPEDANCE:1.111MΩ*ACCURACY:±0.5%*FREQUENCY B.W.:DC~50MHz*WORKING POWER:MAX. 1Watt*INPUT VOLTAGE:MAX.250VDC or 200V rms AC*DIMENSION:48mm(L)xΦ16mm(D)*WEIGHT:25g*APPLICATION: Matching the impedance of the Scope probe with the DMM. with this converter, the user can use the oscilloscope to watch the wave from and measure the precise reading from the DMM.
-
EQSFP28 -
Optellent, Inc.
The OPTELLENT EQSFP28 is a cost-effective and convenient test board for testing QSFP28 optical transceivers in R&D and manufacturing environments. The EQSFP28 is equipped with high quality RF connectors for data signals and test points for low frequency control and status signals. The EQSFP28 is equipped with power supplies to enable voltage margining. Key status signals are displayed using LED indicators.
-
SoMat
With decades of experience in equipping engineers with the right tools to accelerate their R&D testing, HBM is the trusted global partner with a vast knowledge base in automotive and commercial vehicles. Our specialty has always been developing innovative products and all necessary services to create overall solutions covering customers highest testing demands - in the lab, field or bench.
-
EQSFP10 -
Optellent, Inc.
The OPTELLENT EQSFP10 is a cost-effective and convenient test board for testing QSFP/QSFP+ optical transceivers in R&D and manufacturing environments. The EQSFP10 is equipped with high quality RF connectors for data signals and test points for low frequency control and status signals. The EQSFP10 is equipped with power supplies to enable voltage margining. Key status signals are displayed using LED indicators.
-
SCHILLER AUTOMATION GmbH & Co. KG
HDMI test adapters and test fixture kits facilitate Source and Sink compliance testing and HDMI cable testing. Our products are used in Certification Testing to CEA 1.3b, 1.4a, 2.0 and 2.1 standards. 1080p and 4K formats are supported. We offer A and D style plug and receptacle connectors, male and female SMA leads, with and without HEAC channels.
-
TOB-BST8-5V1mA -
Xiamen Tob New Energy Technology Co., Ltd
8 Channel Battery Analyzer (0.002-1mA, up to 5V) with Laptop & Software for R&D Battery Materials. TOB-5V1mA Button Battery Tester is an eight-channel battery analyzer to analyze small coin cells with a range current 0-50mah, voltage 0-5v. Each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software.
-
RSA5000 -
Rigol Technologies Inc.
The RSA5065 real-time spectrum analyzer with real-time analysis and sweep analysis, optional vector signal analysis application software (VSA) and EMI measurement application software (EMI), with excellent performance and specifications. Its frequency range is 9kHz to 3.2GHz, and it is available with the tracking source "-TG" model, which can be widely used in enterprise R&D, factory production, education and teaching.
-
DSG3000B -
Rigol Technologies Inc.
The DSG3000B Series offers continuous wave high power carriers up to 13.6 GHz, standard AM/FM/ØM analog modulation up to 3.6 GHz, and I/Q modulation and I/Q baseband output up to 6.5 GHz on the models ending in "IQ". It is an ideal tool in various fields such as communication, computers, instrumentation, R&D, education, production and maintenance.
-
VA520/VA520B -
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
The digital LCR meter is equipped with a user-friendly panel. It is housed in an insulated enclosure for enhanced safety. The USB interface allows easy connection to computers. Available in 19,999 or 1,999 counts. Dual-LCD design. Analog bar display. Mini USB port. Parameter: Ls, Lp, Cs, Cp, DCR, ESR, D and Q. Relative measurement. Data hold function. With backlight.
-
KU-2600 -
Kaise Corporation
4000 count LCD 2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x2)CATⅡ600V, CATⅢ 300V compliant155(H) x 75(W) x 29(D) mm,Approx. 180gHolster, 100-50 Test Leads, 1.5V R6P Batteries (x2 & spare),Spare Fuses F14 (0.5A/250V) (x1), Spare Fuses F17 (10A/250V) (x1),
-
ADC Corporation
Realizes 46 readings per second (60Hz) at integration time of 1 PLC that is the highest sampling rate in this class, contributing to the takt time reduction and the quality improvement in production lines. In addition, these models are capable of easy measurement data transfer through a laptop computer with the USB interface, so that they provide smart data analysis in R&D as well as production lines.
-
TS File Demux -
DVBStreamExplorer
TS File Demux will extract/demux various streams such as ES, PES, sections and partial TS from a MPEG2 Transport Stream to separate files. The extracted files can then be used for input in other software, i.e. analyzing applications. TS File Demux is ideal for R&D labs that work with MPEG2 Transport Streams. TS File Demux is used internally for development of DVBStreamExplorer application.
-
Hamamatsu Photonics K.K.
The C10066-10 Immunochromato-Reader makes rapid, high sensitivity, quantitative measurements of color intensities for red/blue-based immunochromatographic reagents. Since measurement data is saved as a CSV file, it can be analyzed on commercially available spreadsheet software, and calibration curve and time-course graphs then easily drawn. The C10066-10 Immunochromato-Reader is an optimal tool for R&D work as well as quality control of immunochromatography reagent kits.
-
Shimpo Instruments
SHIMPO INSTRUMENTS offers a variety of sensors and rotary pulse generators to send various trigger signals to panel tachometers, counters and stroboscopes. When coupled with the appropriate SHIMPO panel meter or stroboscope, our sensors can be used in many different operating environments from laboratory to hazardous Class I -Group C&D and Class II- Group E, F, & G.
-
GX3348 -
Terotest Systems Ltd.
The GX3348 is a multi-channel analog I/O 6U PXI card which provides (3) programmable sources, and a 4 x 48 or 4 x 64 matrix - allowing the user to route the 3 sources, or ground to any of the 48 or 64 I/O channels. In addition, each I/O channel can be connected to a 16-bit A to D converter, providing DC voltage measurement capability for each channel.